Abstract

To the Editor: A 73-year-old man presented to Department of Cardiology at Xinhua Hospital, Shanghai Jiaotong University School of Medicine with a history of anterior wall myocardial infarction (MI) and multimorphic ventricular tachycardia (VT) in approximately September 2013. His VT burden became progressive increase despite treatment with percutaneous coronary intervention (PCI) and multiple antiarrhythmic medications such as beta blockers, amiodarone, magnesium sulfate, and so on. One month after PCI, the patient received an implantable cardioverter defibrillator (ICD) (Marquis, Medtronic, USA) implantation due to complex ventricular arrhythmias and depressed left ventricular ejection fraction (36%). The detection and therapy programming of the device included 2 zones: ventricular fibrillation (VF) zone (rate > 188 beats/min) and VT zone (rate 150–188 beats/min to VF zone). Later, the patient started to experience palpitations and shocks during physical activity. One month after the ICD implanted, the patient had to have the first radiofrequency catheter ablation (RFCA). Electroanatomic substrate mapping demonstrated a large area (53 cm2) of low amplitude electrograms (<0.5 mv) consistent with scar extending forward from the septum over to the lateral aspect of the heart [Figure 1]. Programmed stimulation induced two types of VT, VT1 (cycle-length (CL) 380 ms) “nonclinical” and the remaining VT2 (CL 430 ms) “clinical” as determined predominantly from the intracardiac electrogram morphology and CL analysis. A limited activation map demonstrated early activation at the apex and the lateral aspect of the scar, with a local electrogram preceding the onset of the QRS by approximately 70 ms. Entrainment mapping near these locations demonstrated concealed entrainment with a postpacing interval minus tachycardia CL of 15 ms. Ablation at these sites resulted in immediate VT termination. Figure 1 The electroanatomic map (right anterior oblique view) and ventricular tachycardia morphology. The top panel: electroanatomic map of the initial ablation procedure in a patient with recurrent ventricular tachycardia (VT). Brown tags indicated sites with ... Two weeks after the first RFCA, incessant, tolerated, slow (120–150 betas/min) VTs were detected by electrocardiogram monitoring, and these VTs were neither identified by ICD nor responded to multiple anti-arrhythmic medications. The ICD device was reprogrammed and new antitachycardia pacing (ATP) algorithms (VT zone: rate 130–188 beats/min) were performed, but this adjustment was failed and ended with shock therapy. To reduce the risk of receiving an inappropriate shock, the patient had a second RFCA treatment 1-month later. The area of second scarring had a larger scar (69 cm2) as assessed by electroanatomic mapping compared with the first, and the VT3 (CL 500 ms) critical isthmus was limited to the new region, which was “adjacent” to prior ablation lesions [Figure 1]. Radiofrequency lesions were placed at the new scar site and extended to the sites of late potentials in order to consolidate the lesions. Following ablation, VTs could no longer be induced. The procedure went well and there were no evidences of recurrent VTs and shock during 6 months postoperative follow-up. Several factors influence the termination of VT by ATP. The distance between the pacing site and the VT circuit may critically affect the ATP effectiveness.[1] Small changes in the VT CL were useful in predicting the ATP success.[2] In the present case, although an episode of VT had initiated, as the R-R intervals fluctuated beyond the detection threshold of ATP therapy, the device did not perceive these VT events, consequently ATP therapy was withheld. Little is known about the reason for recurrent VT after acutely “successful” catheter ablation.[3] Progressive fibrosis and remodeling may lead to the development of VT after the index event. Continued infarct remodeling may lead to the formation of new VT circuits that were not present during the initial ablation session.[3,4] In this case, the present patient had recurrent VTs that were resistant to treatment with antiarrhythmic drugs and ICD. The coexistence of three conditions is rare, and it is a challenge to treat. Some VTs failed to ATP therapy can lead to a delay in appropriate therapy, even contribute to a negative consequence. Thus, RFCA has become an important tool for the successful management of these VTs. It could result in the prevention of future VTs by ablating regions of slow conduction,[3] and all late potentials.[5] Hence, it is possible and effective for us to finish a linear pattern of lesions through sites of late potentials and good pace-maps.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call