Abstract
In the design of the cost function in the nonlinear finite control set model predictive control (FCS-MPC) system, the traditional method based on weighting factors demonstrates some limitations, such as the weighting factors adjusting and heavy predictive calculation due to the increased number of voltage vectors applied in controlling multilevel converters. This paper proposes a simplified FCS-MPC method based on common mode voltage satisfactory optimization, which could considerably reduce the predictive calculation by the optimized switch combination and simplify the cost function design. Moreover, satisfactory optimization is adopted to achieve the accuracy control of common-mode voltage amplitude without adjusting process of weighting factors. The simulation and experimental results verify the feasibility of this control strategy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Chaos, Solitons and Fractals: the interdisciplinary journal of Nonlinear Science, and Nonequilibrium and Complex Phenomena
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.