Abstract

Combined with the project which a grain silo need be transformed, a new type of silo is put forward. The silo system consists of supporting columns, the silo body and latticed shell roof structure. In view of the force is different between silo shell roof and conventional roof, and silo shell roof prones to buckling failure. The linear and nonlinear buckling analysis was carried out for latticed shell with a diameter of 20m, the results show that the buckling loads obtained by linear buckling analysis is greater than that obtained by nonlinear buckling analysis, and nonlinear analysis is more secure for structures. Through the comparison the rationality and stability of reticulated shell design are verified, finally construction measures of this system are given, and these can provide references for design and construction of similar engineering.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.