Abstract

Development of antiinflammatory drugs for lung diseases demands novel methods for noninvasive assessment of inflammatory processes in the lung. To investigate the feasibility of hyperpolarized 129 Xe MRI, 1 H T1 time mapping, and dynamic contrast-enhanced (DCE) perfusion MRI for monitoring the response of human lungs to low-dose inhaled lipopolysaccharide (LPS) challenge compared to inflammatory cell counts from induced-sputum analysis. Prospective feasibility study. Ten healthy volunteers underwent MRI before and 6 hours after inhaled LPS challenge with subsequent induced-sputum collection. 1.5T/hyperpolarized 129 Xe MRI: Interleaved multiecho imaging of dissolved and gas phase, ventilation imaging, dissolved-phase spectroscopy, and chemical shift saturation recovery spectroscopy. 1 H MRI: Inversion recovery fast low-angle shot imaging for T1 mapping, time-resolved angiography with stochastic trajectories for DCE MRI. Dissolved-phase ratios of 129 Xe in red blood cells (RBC), tissue/plasma (TP) and gas phase (GP), ventilation defect percentage, septal wall thickness, surface-to-volume ratio, capillary transit time, lineshape parameters in dissolved-phase spectroscopy, 1 H T1 time, blood volume, flow, and mean transit time were determined and compared to cell counts. Wilcoxon signed-rank test, Pearson correlation. The percentage of neutrophils in sputum was markedly increased after LPS inhalation compared to baseline, P = 0.002. The group median RBC-TP ratio was significantly reduced from 0.40 to 0.31, P = 0.004, and 1 H T1 was significantly elevated from 1157.6 msec to 1187.8 msec after LPS challenge, P = 0.027. DCE MRI exhibited no significant changes in blood volume, P = 0.64, flow, P = 0.17, and mean transit time, P = 0.11. Hyperpolarized 129 Xe dissolved-phase MRI and 1 H T1 mapping may provide biomarkers for noninvasive assessment of the response of human lungs to LPS inhalation. By its specificity to the alveolar region, hyperpolarized 129 Xe MRI together with 1 H T1 mapping adds value to sputum analysis. 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1669-1676.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call