Abstract
Purpose: Experimental determination of the response room function and its use to estimate the acoustic conditions in rooms with noncontinuous noise sources.Methodology/approach: The detailed parameter calculation of noncontinuous sound fields using the response room function, which is the room response to pulse excitation. The response function can be calculated by analytical or numerical methods and by experimental measurements in production conditions the energy attenuation when a constant noise source is switched off.Findings: Noncontinuous noise has a negative impact on health. The effective noise reduction is determined by the complete and accurate analysis of its energy parameters. The noncontinuous noise estimation based on equivalent levels does not meet the requirements, especially when pulsed noise sources are active. The experimental technique is proposed for the response function calculation and its use in evaluating the noise conditions in rooms with noncontinuous noise sources.Practical implications: The experimental determination of the response function to pulse excitation allows studying the acoustic processes in rooms for the formation of noise conditions when analytical methods cannot be used. The experimentally obtained response function makes it possible to solve problems of changing the noise conditions in rooms with noncontinuous noise sources.
Highlights
В работе предлагается выполнить подробный расчет параметров непостоянных звуковых полей на основе функции отклика помещения, которая представляет реакцию помещения на импульсное возбуждение
Experimental determination of the response room function and its use to estimate the acoustic conditions in rooms with noncontinuous noise sources
Noncontinuous noise has a negative impact on health
Summary
В работе предлагается выполнить подробный расчет параметров непостоянных звуковых полей на основе функции отклика помещения, которая представляет реакцию помещения на импульсное возбуждение. В результате исследования предложена экспериментальная методика определения функции отклика и показаны возможности ее использования для оценки шумового режима в помещениях с непостоянными источниками шума. NONCONTINUOUS NOISE CALCULATED BY ROOM RESPONSE FUNCTION DETERMINED BY EXPERIMENTAL DATA For citation: Antonov A.I., Ledenev V.I., Matveeva I.V., Porozhenko M.A. Raschet nepostoyannogo shuma s ispol''zovaniem funktsii otklika pomeshcheniya, opredelyaemoi po eksperimental''nym dannym [Noncontinuous noise calculated by room response function determined by experimental data].
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Vestnik Tomskogo gosudarstvennogo arkhitekturno-stroitel'nogo universiteta. JOURNAL of Construction and Architecture
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.