Abstract

A non-adiabatic tapered fiber sensor coated with humidity-sensitive graphene oxide (GO)/Poly (vinyl) alcohol (PVA) nanocomposite film for humidity sensing application was proposed. GO/PVA film was deposited onto the tapered region by dip-coating technique. The surface morphology of the coating film was characterized through Field Emission Scanning Electron Microscope (FESEM). When exposed to percent relative humidity (RH) ranging from 20 to 99.9 % RH, the sensor exhibited sensitivity for both untapered and tapered fibers at −0.00132 ± 0.00043 a. u (%)−1 and 0.00106 ± 0.00008 a. u (%)−1, respectively. The contribution of GO/PVA composite film in enhancing sensor sensitivity was proven, which was 0.00624 ± 0.00033 a. u (%)−1 with percentage of sensitivity boosting up to 15.86 % when compare to the uncoated ones.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.