Abstract

The ways of increasing the sensitivity of a non-selective thermal radiation receiver based on cadmium antimony using the phenomenon of electromagnetic induction are considered and investiga­ted. It has been shown that the application of ani­sotropic NdFeB anisotropic magnet increases the volt-watt sensitivity of the thermal radiation recei­ver by 30 %. When a more powerful magnet is used, an additional increase in sensitivity is observed, but not in proportion to the magnitude of the additio­nal magnetic induction. The dynamic range of the created thermal radiation receiver, which is from 10 to 200000 W/m-2, is investigated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.