Abstract

Objectives: Retrieving the accurate time-tracer activity concentration curve of the blood (arterial input function) is mandatory for performing bio kinetic model analysis of dynamic PET data. Especially in small rodents, gathering the input function remains an active area of research as no generally applicable solution was found so far. While surgically catheterizing blood vessels of rodents is possible, it is labour intensive and time resolution of blood sampling is restricted due to the limited amount of overall blood and the procedure of blood withdrawal itself. Obtaining the input function from the PET images themselves seems thus to be favourable, but suffers from several factors, one of them being spill-in of adjacent tissues. Particularly in mice and for [18F]FDG, the spill-in complicates using the time-activity curve (TAC) from a region of interest (ROI) over the left ventricle (LV) because the signal of the ROI contains contributions from both, myocardial uptake as well as arterial blood activity. We propose non-negative matrix factorization (NMF) as an image based algorithm for separating myocardial tracer concentration from the blood input function. The aim of this study was to evaluate the potential of NMF as an image based algorithm for retrieving the input function by comparison with blood sampling and Factor Analysis (FA). Method: The femoral arteries of eight mice were surgically catheterized. With the injection of [18F]FDG, a 60 minute PET scan was started during which arterial blood samples were manually drawn from the catheter. For analysis, NMF and FA were performed in a ROI placed over the LV. The NMF algorithm shares similarities with principal component analysis and FA, the advantage over the later two being its non-negativity constraint. For normalization of the NMF extracted curve, the peak value of tracer activity in an early image of the LV and a late blood sample was used. The normalized NMF curve was visually compared to the TAC retrieved from the blood samples and to the FA retrieved TAC. For a quantitative comparison of performance, Pearson correlation and square-root of sum of squares (RSS) between NMF/FA and blood sampling curves was calculated. Results: TAC based on NMF, FA and arterial blood samples were obtained and compared in all 8 mice. The NMF derived curves described the blood sampling based curves visually significantly better than FA. Pearson correlation between NMF and blood sampling curves ranged from 0.21 to 0.92 with an average of 0.69. Pearson correlation for FA ranged from 0.46 to 0.81 with an average of 0.65. Mean RSS was 2.70E + 006 for NMF and 3.40E + 006 for FA. Conclusion: In the examined parameters, visual accordance, Pearson correlation and RSS, NMF performs superior to FA and seems to be a promising method for the extraction of the input function from PET images of small rodents without the need for arterial blood sampling.

Highlights

  • Due to its ability for visualizing functional processes and precise quantification of radiotracer uptake, positron emission tomography (PET) became a widely used tool for small animal imaging

  • time-activity curve (TAC) based on negative matrix factorization (NMF), Factor Analysis (FA) and arterial blood samples were obtained and compared in all 8 mice

  • In the examined parameters, visual accordance, Pearson correlation and RSS, NMF performs superior to FA and seems to be a promising method for the extraction of the input function from PET images of small rodents without the need for arterial blood sampling

Read more

Summary

Introduction

Due to its ability for visualizing functional processes and precise quantification of radiotracer uptake, positron emission tomography (PET) became a widely used tool for small animal imaging. While in humans and larger animals such as primates or even rats, samples can be taken continuously using an arterial catheter, in mice, the necessary micro surgical preparation is labour intensive and limited regarding timing resolution due to the low total amount of blood in the animal [1]. This can lead to undersampling of the peak of the activity in the arterial blood, which appears in mice approximately 15 s after injection of the tracer into the tail vein. Surgical intervention makes it difficult to perform repetitive studies in the same animal

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.