Abstract

Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification. MRI and dynamic PET images were obtained from a recent study investigating treatment effects in 12 mice following myocardial infarction [1], where half the mice received a new treatment and half did not. Prospectively gated MRI (4.7T Bruker BioSpec, FLASH TR/TE 400/3ms, spatial resolution 140μm in 1mm slices) were acquired prior to PET acquisition (approx. 25MBq 18F-FDG bolus, 45 minute emission listmode acquisition reconstructed with 3DRP in four cardiac frames) on a split-magnet PET camera [2]. Images were co-registered using SPMMouse [3] (see Figure ​Figure11). Figure 1 Mouse heart MR (left) and fused with 18F-FDG static PET (right). Arrow indicates infarcted region. AIF extraction AIFs were obtained by taking mean time courses from LV Lumen ROIs, shown in Figure ​Figure2.2. The regional geometric transfer matrix (GTM) method was applied for PVC [4], using ROIs drawn on either the co-registered MR images or directly onto the last dynamic frame PET images. ROIs covered LV lumen, myocardium, lungs/body and background. Patlak [5] analysis was performed to evaluate glucose metabolism. Figure 2 AIFs and TACs derived for single subject using (A) MR ROIs, (B) PET ROIs with PVC and (C) MR ROIs with PVC. Insets detail first 500s Uncorrected AIFs and myocardial TACs produced by manual ROI delineation displayed contamination with myocardial signal. AIFs and myocardial curves became distinguishable if GTM PVC was applied. Only MR-based PVC produced significant differences (p<0.05) in Ki values between the treated and untreated groups (see Table ​Table11). Table 1 GTM-based PVC gives best results in mice when ROIs are based on MRI data, due to its high-resolution and excellent soft-tissue contrast.

Highlights

  • Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma

  • The regional geometric transfer matrix (GTM) method was applied for partial volume correction (PVC) [4], using ROIs drawn on either the co-registered MR images or directly onto the last dynamic frame PET images

  • ROIs covered left ventricle (LV) lumen, Figure 2 AIFs and TACs derived for single subject using (A) MR ROIs, (B) PET ROIs with PVC and (C) MR ROIs with PVC

Read more

Summary

Introduction

Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. MRI and dynamic PET images were obtained from a recent study investigating treatment effects in 12 mice following myocardial infarction [1], where half the mice received a new treatment and half did not. Gated MRI (4.7T Bruker BioSpec, FLASH TR/TE 400/3ms, spatial resolution 140μm in 1mm slices) were acquired prior to PET acquisition

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.