Abstract

Background: Treatment of distal tibial metaphyseal fractures is often challenging and no single technique has been unanimously advocated. Open reduction and internal fixation with plates and screws allows better restoration of anatomical alignment but with more soft tissue complication. Simultaneous fixation of the fibula is not universally carried out. This study aims at evaluation of the outcome of plating technique and the effect of fixation of fibula fracture in treatment of distal tibial metaphyseal fractures.
 Material and methods: Thirty-one cases (14 cases in Group A with concomitant distal fibula fracture and 17 cases in Group B without distal fibula fracture) were analyzed retrospectively for the mean duration of full weight bearing, mean union time and complications, and compared.
 Results: The mean time for full weight bearing and radiological union in our study was 14.2 weeks (15.9 in Group A and 13.1 in Group B) and 23.8 weeks (26.6 in Group A and 21.5 in Group B) respectively. 16.1% of cases had post-operative complications including one case of deep infection and malalignment of 6 degree varus (following delayed union) was seen in one case of Group A. Range of motion (ROM) at ankle was not problem in any of the cases except the one delayed union which had 5 degrees of dorsiflexion and 15 degrees of plantiflexion.
 Conclusion: Open reduction and internal fixation with plate and screws in distal tibial metaphyseal fracture is more economic means of treatment modality with comparable incidence of post-union malalignment and union time,though more soft tissue complications compared to other modalities. Fixation of fibula fracture aids in reducing the incidence of malalignment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call