Abstract

The paper proposes a fast dynamic mathematical model to evaluate the performances of saturated permanent magnet synchronous machines (PMSM) under stator winding’s inter turn fault. The parameters of the model can be determined using only manufacturer’s data of the healthy machine. Two surface mounted PMSM have been considered to investigate the validity of the proposed approach; with distributed and concentrated winding. It has been shown that the proposed model predicts the fault current with a reasonable accuracy compared to the non-linear Finite Elements analyses and to the experimental results. This model can be incorporated in a global simulation environment of power electronic of electrical device since the computation time is very short.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.