Abstract

Heart rate is a crucial physiological indicator for fish, but current measurement methods are often invasive or require delicate manipulation. In this study, we introduced two non-invasive and easy-to-operate methods based on photoplethysmography, namely reflectance-type photoplethysmography (PPG) and remote photoplethysmography (rPPG), which we applied to the large yellow croaker (Larimichthys crocea). PPG showed perfect synchronization with electrocardiogram (ECG), with a Pearson's correlation coefficient of 0.99999. For rPPG, the results showed good agreement with ECG. Under active provision of green light, the Pearson's correlation coefficient was 0.966, surpassing the value of 0.947 under natural light. Additionally, the root mean square error was 0.810, which was lower than the value of 1.30 under natural light, indicating not only that the rPPG method had relatively high accuracy but also that green light may have the potential to further improve its accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.