Abstract

Abstract Centrifugal compressors can suffer from rotordynamic instability. While individual components (e.g., seals, shrouds) have been previously investigated, an integrated experimental or analytical study at the compressor system level is scarce. For the first time, non-axisymmetric pressure distributions in a statically eccentric shrouded centrifugal compressor with eye-labyrinth seals have been measured for various eccentricities. From the pressure measurements, direct and cross-coupled stiffness coefficients have been determined. Thus, the contributions of the pressure perturbations in the shroud cavity and labyrinth seals have been simultaneously investigated. The cross-coupled stiffness coefficients in the shroud and labyrinth seals are both positive and one order of magnitude larger than the direct stiffness coefficients. Furthermore, in the tested compressor, contrary to the common assumption, the cross-coupled stiffness in the shroud is 2.5 times larger than that in the labyrinth seals. Thus, not only eye-labyrinth seals but also shrouds need to be considered in rotordynamic analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.