Abstract

A multimode sensor (a sensor responding simultaneously to more than one mode, e.g., stochastic mode, amperometric mode, voltammetric mode) based on graphite paste modified with N-methylfulleropyrrolidine was proposed for the determination of butoconazole nitrate in its pharmaceutical formulation. The stochastic mode and square wave voltammetry mode were applied for the determinations. Both the stochastic mode and square wave voltammetry mode were applied for a qualitative and quantitative assay of butoconazole nitrate. The sensor can be used between 1.68 × 10-6 and 1.68 × 104 μmol L-1 when the stochastic mode is used and between 0.168 and 16.80 μmol L-1 when the square wave voltammetry mode is used. The multimode sensor was reliably used for the determination of butoconazole nitrate in its pharmaceutical formulation, Gynofort cream, the recorded recoveries being higher than 99.00%, with RSD (%) values of lower than 2.00%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.