Abstract

This paper presents the research results on the corrosion inhibition effect of benzotriazole on copper M-1 and aluminum AK-7 in 5% citric acid solution. Electrochemical test resultsshow that benzotriazole as a good corrosion inhibitors for copper M-1 and aluminum AK-7. The optimal protective concentration of benzotriazole in this condition is 0.5%, at which the protective effect for copper M-1 and aluminum AK-7 is 75.43% and 69.56% respectively. After 2 hours of corrosion test in glassware at 88±2°C by mass loss method with a concentration of 0.5% benzotriazole, the protective effect for copper M-1 and aluminum AK-7 reaches 69.1% and 65.4% respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call