Abstract

Objective To test the ability of a modified pulmonary artery (PA) monitoring catheter to detect distal catheter migration. Design Prospective nonrandomized trial. Patients Surgical ICU patients requiring invasive hemodynamic monitoring. Interventions Eight patients received PA catheters modified to include a right ventricular (RV) pressure monitoring port located 7 cm from the tip. Fifteen patients received catheters with an RV port located 10 cm from the tip. Guided by the RV port pressure waveform, catheters were initially positioned so that the RV port was located just proximal to the pulmonic valve. Measurements and main results Pulmonary capillary occlusion pressure (PAOP) could not be obtained in six of the eight patients receiving the 7-cm RV port catheter unless the RV port was advanced into the PA. PAOP was consistently obtained in all 15 patients receiving the 10-cm RV port catheter, with the RV port positioned in the RV. Chest radiographs confirmed a central PA catheter position. In this group, distal migration of the catheter occurred 14 times in eight patients, as detected by appearance of a PA pressure waveform at the RV port. Distal migration was corrected by withdrawal of the catheter until an RV waveform reappeared at the RV port. Conclusions We conclude that distal catheter migration occurs frequently with PA monitoring catheters, but can be detected at the bedside with a catheter modified to include an RV port 10 cm from the tip. This new catheter may add a margin of safety to PA monitoring and lower its overall cost by eliminating the need for chest radiographs ordered solely to confirm catheter tip location.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call