Abstract

In the previous study, we proposed a new interfacial drag force model based on experimental data of steam-water bubbly flow in a large-diameter pipe. This is because our experimental results had suggested that effect of bubble wake should be included in the interfacial drag force model, although it had not been taken into account in the existing models. A preliminary method for including the effect of bubble wake was hence developed and used in the new model. A new bubble size prediction method was also adopted in the model. In the present study, after improving the measuring equipment and signal processing procedure, another series of experiments was carried out. Using the new experimental data, the methods of predicting bubble size and effect of bubble wake were slightly modified. To test the validity of the new model, predicted results were compared with available experimental data sets of steam-water bubbly two-phase flow in large-diameter pipes. One-dimensional and two-dimensional two-fluid models we...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.