Abstract

The High Temperature Helium Loop (HTHL) is an experimental device for simulation of VHTR helium coolant conditions. The purpose of the HTHL is structural materials testing and helium coolant chemistry investigation. In the HTHL pure helium will be used as working medium and its main physical parameters are 7MPa, max. temperature in the test section 900°C and flow rate 37.8kg/h. The HTHL consists of an active channel, the helium purification system, the system of impurities dosage (e.g. CO, CO2, H2, H2O, O2, N2, and CH4) and the helium chemistry monitoring system (sampling and on-line analysis and determination of impurities in the helium flow). The active channel is planned to be placed into the core of the experimental reactor LVR-15 which will serve as a neutron flux source (max. 2.5×1018n/m2s for fast neutrons).The HTHL is now under construction. Some of its main parts are finished, some are still being produced (active channel internals, etc.), some should be improved to work correctly (the helium circulatory compressor); certain sub-systems are planned to be integrated to the loop (systems for the determination of moisture and other impurities in helium, etc.). The start of the HTHL operation is expected during 2011 and the integration of the active channel into the LVR-15 core during 2012.