Abstract
Earlier studies have demonstrated the strong relationships between manual assembly work with a high repetition level and the presence of repetitive strain injuries (RSI) or repetitive motion illnesses (RMI). Moreover, recent works have also correlated the high physical load level in assembly lines with an increased number of quality defects in finished products. Thus, the ergo-quality level of a manual workstation needs to be carefully monitored not only to respond to the legislation but first of all to ensure a high system productivity level in the medium-term perspective. The objective of this study was to develop and test a new easy-to-use postural assessment tool and its performance in a car component assembly system. The results show the promising potential of the methodology particularly when compared with the well-known OCRA method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.