Abstract

BackgroundPreviously, results of the digital flicker test (DFT) have shown distinct patterns in acute optic neuritis (ON) and healthy eyes. We aimed to examine the diagnostic potential of the DFT in acute ON and to investigate the temporal development of the DFT response following ON while comparing with visual evoked potentials (VEP). MethodsThe DFT examines the subjective brightness of a flickering field, varied in 11 different frequencies from 0 to 60 Hz, compared to a steady field. Previous studies have indicated a pronounced darkness enhancement at medial frequencies in acute ON eyes. Darkness enhancement at medial frequencies was expressed as a quantitative covariate (DFTDE). Results were compared with healthy controls and follow-up measurements were compared with VEP. Results112 patients were examined <31 days of onset (median 14.0 days (IQR:12.25)). 104 of 112 patients showed an abnormal flicker test (sensitivity 93%). DFT was abnormal in 2 of 55 healthy controls. The DFT showed normalization in 34% at 3 months, 36.4% at 6 months and 71.4% at >8 months from ON onset compared to 13.3%, 22.4% and 28.6% for VEP. Changes to the pattern of the DFT results were shown at specific stages during and following ON. ConclusionsThe DFT is an easy-to-use and sensitive diagnostic test for acute ON. The flicker test shows a more pronounced temporal evolution following ON than VEP and may be of use monitoring the course of ON.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call