Abstract
Two alternative BIST schemes are proposed for structural testing of pipelined Analog-to-Digital Converters (ADC). They are oriented to fault detection in the converter stages rather than to measure the whole ADC electrical performance parameters. The operational principle of both strategies relies on testing every ADC stage reconfigured as an A/D-D/A block and applying as input a simple DC stimuli set which is easily obtained, without strong precision requirements, by a resistive network. The main differences between both strategies relate to the way the output response is evaluated. In the BISTn1 scheme, analog and digital outputs are compared with reference levels generated with a reference D/A converter and a counter. In the BISTn2 strategy, only digital outputs are available and they are compared with fault-free values previously stored in an on-chip register. The new techniques are intended to be used in pipelined converters of an arbitrary number of conversion stages and with a digital self-correction mechanism.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.