Abstract

We have studied the peak shapes at 596 and 691 keV resulting from fast neutron interactions inside germanium detectors. We have used neutrons from a 252Cf source, as well as from the 28Si(μ −, nv), and 209Bi(π −, xn) reactions to compare the peaks and to check for a dependence of peak shape on the incoming neutron energy. In our investigation, no difference between these three measurements has been observed. In a comparison of these peak shapes with other studies, we found similar results to ours except for those measurements using monoenergetic neutrons in which a significant variation with neutron energy has been observed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.