Abstract
The design and operation of instrumentation included in the gas injection system of the Tokamak Fusion Test Reactor (TFTR) for torus pressure and gas flow measurements are described. Magnetically shielded ion gauges, located on the torus boundary, are used for fast (1 kHz) torus pressure measurements over the range 10−7–10−3 Torr. Gas injection assemblies comprising an array of piezoelectric gas injection valves are situated at three toroidal locations. The gas injection valves are programmed for various discharge conditions including feedback control from the torus pressure gauges and plasma density measurement. Gas flow through the injection valves is monitored by strain-gauge-type pressure transducers on each injection valve. The resulting gas flow measurements are used for gas fueling, particle balance, and recycling studies.