To identify the current practice of administration of gadolinium-based contrast media (Gd-CM) within the UK with respect to the European Society of Urogenital Radiology (ESUR) guidelines on nephrogenic systemic fibrosis (NSF). One hundred and fifty-two institutions were contacted to request details regarding the use of Gd-CM at their institution, their awareness of NSF, and of the ESUR guidelines, and their departmental policy on the administration of Gd-CM agents associated with NSF (high-risk agents) in patients with diminished renal function. Of the 100 institutions that replied, 72% used a cyclic agent as a first-line Gd-CM. The majority of institutions used more than one Gd-CM, and 57% used a high-risk Gd-CM. Seventy percent were aware of the ESUR guidelines, and of the 57% that used a high-risk Gd-CM, 9% did not check renal function at all prior to administration. The course of action of the remaining 48% was varied in patients with diminished renal function with some changing to a low-risk Gd-CM and others electing not to use Gd-CM at all. Five percent continued to use a high-risk Gd-CM with an estimated glomerular filtration rate <30ml/min. The present survey shows that the majority of institutions use a low-risk Gd-CM as a first-line agent; however, a number of institutions do use a high-risk Gd-CM and their course of action for patients with diminished renal function is varied. Given current evidence, it is advisable to use a low-risk Gd-CM, such as a cyclic agent, in patients with diminished renal function.