Abstract
We report magnetic manipulation of non-magnetic particles suspended in diluted ferrofluid. Diamagnetic particles were introduced into a circular chamber to study the extent of their deflection under the effect of a non-uniform magnetic field of a permanent magnet. Since ferrofluid is a paramagnetic medium, it also experiences a bulk magnetic force that in turn induces a secondary flow opposing the main hydrodynamic flow. Sheath flow rate, particle size, and magnetic field strength were varied to examine this complex behaviour. The combined effect of negative magnetophoresis and magnetically induced secondary flow leads to various operation regimes, which can potentially find applications in separation, trapping and mixing of diamagnetic particles such as cells in a microfluidic system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.