Abstract
Abstract We propose a quantitative x-ray phase imaging technique using previously demonstrated XOR objectives. The fabrication process of XOR is identical to that of a Fresnel zone-plate and as a result the same finest outermost zone width, thus spatial resolution, can be achieved. A series of phase shifts from 0 to 2 π is implemented by shifting the relative position of the grating with respect to the zone-plate. Both qualitative differential interference contrast imaging and quantitative phase reconstruction are demonstrated. We expect this high-resolution quantitative x-ray phase imaging capability to further enhance the utility of existing x-ray microscopy facilities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.