Abstract

It is a common practice that the synchronous machines, induction machines and other rotating machines are modeled in dqO reference frame. However, the external network (transmission lines, etc) is mostly modeled in the phase-domain reference frame. Therefore, if a rotating machine can be modeled in phase-domain reference frame, we can construct the electric network model without reference frame transformation. In this paper, we derive the phase-domain model of an induction generator in terms of instantaneous values, and its validity is analyzed based on numerical simulations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.