Abstract

This paper presents a new method for precision measurement of axial and angular motion errors in the main rotational axis of a manufacturing machine. Three displacement sensors and one angle sensor are used in this method. Applying a calculation technique, it is possible to separate axial motion error, two angular motion errors, and the circumference profile. The principle of this method is examined from the viewpoint of spatial frequency analysis. From this principle, it appears that this new method can measure all spatial frequencies, without omitting any frequency. A measurement system performed experiments. The measurement experiments confirmed the separate measurement of the profile and motion errors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.