Abstract

To validate a magnetic resonance (MR) imaging technique that is not first pass and that reveals perfusion and regional blood volume (RBV) in the intact rat. Measurement of perfusion was based on the perfusion-sensitive T1 relaxation after magnetic spin labeling of water protons. RBV was determined from steady-state measurements of T1 before and after administration of an intravascular contrast agent. The colored microsphere technique was used as a reference method for perfusion measurement. RBV and perfusion maps were obtained with the rats at rest and during administration of 3 mg of adenosine phosphate per kilogram of body weight per minute. At MR imaging, perfusion during resting conditions was 3.5 mL/g/min +/- 0.1 (SEM), and RBV was 11.6% +/- 0.6 (SEM). Adenosine phosphate significantly increased perfusion to 4.5 mL/g/min +/- 0.3 (SEM) and decreased mean arterial pressure from 120 mm Hg to 65 mm Hg, which implies a reduction of coronary resistance to 40% of baseline. RBV increased consistently to 23.8% +/- 0.6 (SEM). The study results show that quantitative mapping of perfusion and RBV may be performed noninvasively by means of MR imaging in the intact animal. The presented method allows determination of vasodilative and perfusion reserve, which reflects the in vivo regulation of coronary microcirculation for a given stimulus.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.