Abstract

A pilot-scale municipal sewage sludge deep-shaft aeration system was implemented in Lanzhou, Gansu Province of China. The reactor depth was 60 m with a diameter of 1.0 m and the sludge to be treated came from a wastewater plant in Lanzhou. In order to obtain the optimum operation conditions, analysis was conducted on the transformations of the volatile suspended solids (VSS), temperature, pH, oxidation-reduction potential (ORP) and pathogens in the deep-shaft reactor under different aeration conditions. Attention was paid to how operating conditions affected the removal efficiency of the VSS and the reaction temperature. As a result, higher volatile solids removal was gained at higher temperature, and the temperature could reach 50.8°C for a complete inactivation of bacteria in the first reaction zone when the deep-shaft aeration system was run for about 18 days. The sludge aeration rate was observed as 1.5 to 1.8 L/(h·L sludge) which enabled the volatile solids removal rate to reach 40.1%. The degradation of VSS occurred under a micro-oxygen environment, and the lowest ORP was found to be -256 mV in the digestive process. Not only aerobic bacteria but also anaerobic and facultative bacteria performed their functions in the reactor.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call