Abstract

AbstractA rapid FTIR spectroscopic method was developed for quantitative determination of the cloud point (CP) in palm oil samples. Calibration samples were prepared by blending randomized amounts of palm olein and palm stearin to produce a wide range of CP values ranging between 8.3 and 47.9°C. Both partial least squares (PLS) and principal component regression (PCR) calibration models for predicting CP were developed by using the FTIR spectral regions from 3000 to 2800 and 1800 to 1600 cm−1. The prediction capabilities of these calibration models were evaluated by comparing their standard errors of prediction (SEP) in an independent prediction set consisting of 14 palm oil samples. The optimal model based on PLS in the spectral range 1800‐1600 cm−1 produced lower SEP values (2.03°C) than those found with the PCR (2.31°C) method. FTIR in conjunction with PLS and PCR models was found to be a useful analytical tool for simple and rapid quantitative determination of CP in palm oil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.