Abstract

Multispectral optoacoustic tomography (MSOT) holds great promise as a non-invasive diagnostic tool for inflammatory bowel diseases. Yet, reliability and the impact of physiological processes during fasting and after food intake on optoacoustic signals have not been studied. In the present investigator initiated trial (NCT05160077) the intestines of ten healthy subjects were examined by MSOT at eight timepoints on two days, one fasting and one after food intake. While within-timepoint and within-day reproducibility were good for single wavelength 800 nm and total hemoglobin (ICC 0.722 to 0.956), between-day reproducibility was inferior (ICC −0.137 to 0.438). However, temporal variability was smaller than variation between individuals (coefficients of variation 8.9% − 33.7% vs. 17.0% − 48.5%). After food intake and consecutive increased intestinal circulation, indicated by reduced resistance index of simultaneous Doppler ultrasound, optoacoustic signals did not alter significantly. In summary, this study demonstrates high reliability and temporal stability of MSOT for imaging the human intestine during fasting and after food intake.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.