Abstract

A method using high-performance liquid chromatography (HPLC) and fluorescence detection is presented for the simultaneous determination of the antiparasitic agents avermectins (abamectin, ivermectin and doramectin) and moxidectin in liver. Samples are extracted using acetonitrile and cleaned up using solid phase extraction on a C18 column, followed by derivatization with trifluoroacetic anhydride. The samples are injected without further cleanup into the HPLC column and any avermectins or moxidectin present are detected using fluorescence detector set at 361 nm excitation and 465 nm emission wavelengths. The limits of quantification are below the stipulated EU Maximum Residue Limit for each of the avermectins and moxidectin. Mean recoveries in bovine liver ranged from 77.5 to 90.8%, with a RSD from 2.7 to 7.7%. The procedure provides a rapid, reliable and sensitive method for determinating avermectin and moxidectin residues in liver of different species (cattle, sheep, pigs). It is also applicable to muscle without modification.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.