Abstract

Recent research has enabled in-vivo examination of mucociliary transit in live airways by analysing the movement patterns of micron-sized markers in high resolution synchrotron X-ray images. However, high levels of false positives and false negatives severely impact the performance of many automated tracking algorithms. This paper proposes an improved approach to track valid mucociliary transit markers using a modified gating region and cost matrix. The proposed method offers a more effective way to associate markers with the correct trackers. Improved visualization methods are also introduced to assist the interpretation of the tracking results. The tracking method has achieved a tracking accuracy of 81.7% track purity and 71.3% track effectiveness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.