Abstract

In this study, we generated 25 multielectron beam (MEB) using an InGaN photocathode with a negative electron affinity state irradiating with 25 multilaser beam. The uniformity of the MEB and the total electron beam current were evaluated. A laser beam was split into 25 laser beams using a spatial light modulator. The coefficient of variation (CV) of laser power was 20%. The CV of quantum efficiency was 1.1%. The CV of electron beam current was 12%, and the total current was about 1.2 μA. These results will enhance the development of the MEB-defect inspection using the InGaN photocathode.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call