Abstract
In this study, we generated 25 multielectron beam (MEB) using an InGaN photocathode with a negative electron affinity state irradiating with 25 multilaser beam. The uniformity of the MEB and the total electron beam current were evaluated. A laser beam was split into 25 laser beams using a spatial light modulator. The coefficient of variation (CV) of laser power was 20%. The CV of quantum efficiency was 1.1%. The CV of electron beam current was 12%, and the total current was about 1.2 μA. These results will enhance the development of the MEB-defect inspection using the InGaN photocathode.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.