Abstract
The purpose of this study was to examine the neurological outcomes after complex lumbosacral surgery in patients undergoing multimodality neurophysiological monitoring. Sixty-one patients were consecutively enrolled in this study. These patients underwent complex intra- and extradural lumbosacral procedures with concomitant intraoperative electromyography (EMG) monitoring of the lower-limb muscles, external anal and urethral sphincters (EAS and EUS), and lower-limb somatosensory evoked potentials (SSEPs). Long-term (minimum 2-year) clinical follow-up data were obtained in all cases. Most patients were treated for spinal/spinal cord tumors (61%) or adult tethered cord syndrome (25%). Recordable lower-extremity SSEPs were reported in 54 patients (89%). New postoperative neurological deficits occurred in only three patients (4.9%), and remained persistent in only one patient (1.6%) at long-term follow-up examination. In only one of these cases was a significant decrease in SSEP amplitude detected. Spontaneous EMG activity was observed in the lower-extremity muscles and/or EAS and EUS in 51 cases (84%). Intraoperatively, EMG demonstrated activity only in the EUS in 5% of patients and only in the EAS in 28%. In seven patients (11%) spontaneous intraoperative EMG activity was observed in both the EAS and the EUS; however, in only three of these cases was EMG activity recorded in both sphincters simultaneously. In addition to spontaneously recorded EMG activity, electrically evoked EMG activity was also used as an intraoperative adjunct. A bipolar stimulating electrode was used to identify functional neural tissue before undertaking microsurgical dissection in 58 individuals (95%). In the majority of these patients, evoked EMG activity occurred either in one (33%) or in two muscles (9%) simultaneously. The presence of electrically evoked EMG activity in structures encountered during microdissection altered the plan of treatment in 24 cases (42%). The authors conclude that the combined SSEP and EMG monitoring of lower-limb muscles, EAS, and EUS is a practical and reliable method for obtaining optimal electrophysiological feedback during complex neurosurgical procedures involving the conus medullaris and cauda equina. Analysis of the results indicates that these intraoperative adjunctive modalities positively influence decision making with regard to microsurgery and reduce the risk of perioperative neurological complications. Validation of the clinical value of these approaches, however, will require further assessment in a larger prospective cohort of patients.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.