Abstract

Multilocus enzyme electrophoresis (MEE) is a standard technique that is used to elucidate the epidemiology of a variety of bacterial species. Recently, the method has been employed by several laboratories for investigations of clinical and foodborne isolates of Listeria monocytogenes. To assess the sensitivity and reproducibility of MEE in characterising L. monocytogenes isolates for epidemiological purposes and, ultimately, to agree on a standard protocol, seven laboratories participated in a blinded study of 80 strains. The strain collection included both epidemiologically related and unrelated isolates. Each laboratory used its own protocol for MEE. The number of enzymes that were assayed by the laboratories ranged from 8 to 23, and the total number of identified electrophoretic types (ETs) varied between 14 and 25. Of the II pairs of duplicate strains, the number of pairs recognised as identical by the seven laboratories ranged from 3 to 10 (median = 8). From 10 to 18 (median = 15) of the 22 groups of epidemiological related strains were recognised as homogeneous by the different laboratories. The discriminatory power of the method, calculated using Simpson's index of diversity for 69 strains (80 strains minus the 11 duplicates), ranged from 0.827 to 0.925. This relatively low discriminatory power is a consequence of a somewhat low genetic diversity of L. monocytogenes compared to other bacterial species. Efforts should be pursued to standardise the method in order to improve the intra- and inter-laboratory reproducibility.