Abstract

One paramount challenge in multi-ion-sensing arises from ion interference that degrades the accuracy of sensor calibration. Machine learning models are here proposed to optimize such multivariate calibration. However, the acquisition of big experimental data is time and resource consuming in practice, necessitating new paradigms and efficient models for these data-limited frameworks. Therefore, a novel approach is presented in this work, where a multi-ion-sensing emulator is designed to explain the response of an ion-sensing array in a mixed-ion environment. A case study is performed emulating the concurrent monitoring of sodium, potassium, lithium, and lead ions, in a medium representative of sweat samples. These analytes are relevant examples of sweat ion-sensing applications for physiology, therapeutic drug monitoring, and heavy metal contamination. It is demonstrated that calibration datasets output by the emulator explain accurately the experimental response of polymeric solid-contact ion-selective electrodes, where root-mean-squared error of 1.37, 1.44, 1.78, 2 mV are obtained, respectively, for Na <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , K <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , Li <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , Pb <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> sensor calibration in artificial sweat. Besides, synthetic datasets of custom size are generated to train, validate, and evaluate different types of multivariate regressors. A Multi-Output Support Vector Regressor (M-SVR) is proposed as a compact, accurate, robust, and efficient multivariate calibration model. It features 13.22% normalized root mean squares, and 20.29% mean root squares improvement compared to a simple linear regression model. It is an unbiased estimator for medium to large datasets, and its average generalization error is of 3.22%. Besides, M-SVR models have a lower computational complexity than single-output SVR or neural network models, making them a suitable solution for memory and energy-constrained edge devices used for continuous and real-time multi-ion monitoring.

Highlights

  • Potentiometric ion-sensors are increasingly applied in many fields, leveraging progress in all-solid-state sensing and technology [1]

  • Accurate ion-monitoring becomes more intricate when the target electrolyte is extremely diluted in the sample, the analyte concentration being of the same order as sensor Limit Of Detection (LOD)

  • The performance of the multi-ion-sensing emulator is assessed and compared with calibration curves obtained from polymeric solid-contact Ion-Selective Electrode (ISE)

Read more

Summary

Introduction

Potentiometric ion-sensors are increasingly applied in many fields, leveraging progress in all-solid-state sensing and technology [1]. They are used for environmental monitoring of pollutants [2], for agricultural soil analysis [2], for water quality control [3], or for biomedical applications such as physiology and healthcare monitoring [4], [5]. The sensor consists in an Ion-Selective Electrode (ISE) coated with a polymeric membrane that selectively entraps the target analyte. Accurate ion-monitoring becomes more intricate when the target electrolyte is extremely diluted in the sample, the analyte concentration being of the same order as sensor Limit Of Detection (LOD)

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call