Abstract

A multichannel motional Stark effect polarimeter system, which is capable of simultaneous measurement of a radial electric field, has recently been developed on the JFT-2M. The diagnostic can measure the polarization angle at 18 radial locations, which cover a region between just inside from the magnetic axis and the outboard edge of the plasma. By viewing two neutral beam lines (one is co-parallel to the plasma current and the other is counter parallel) simultaneously and near tangentially to the toroidal magnetic field from only one spectroscopic instruments, it provides the best sensitivity in radial electric field measurements with good spatial resolution. The magnetic field pitch angle is also measured with the smallest uncertainty. Preliminary data for L-mode plasma has been obtained. It is found that the statistical uncertainty of the magnetic field pitch angle and radial electric field is about 0.1° and 4 kV/m, respectively, with a time resolution of 10 ms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.