Abstract

Electrocardiogram (ECG) has emerged as a widely accepted diagnostic instrument for cardiovascular diseases (CVD). The standard clinical 12-lead ECG configuration causes considerable inconvenience and discomfort, while wearable devices offers a more practical alternative. To reduce information gap between 12-lead ECG and single-lead ECG, this study proposes a multi-channel masked autoencoder (MCMA) for reconstructing 12-Lead ECG from arbitrary single-lead ECG, and a comprehensive evaluation benchmark, ECGGenEval, encompass the signal-level, feature-level, and diagnostic-level evaluations. MCMA can achieve the state-of-the-art performance. In the signal-level evaluation, the mean square errors of 0.0175 and 0.0654, Pearson correlation coefficients of 0.7772 and 0.7287. In the feature-level evaluation, the average standard deviation of the mean heart rate across the generated 12-lead ECG is 1.0481, the coefficient of variation is 1.58%, and the range is 3.2874. In the diagnostic-level evaluation, the average F1-score with two generated 12-lead ECG from different single-lead ECG are 0.8233 and 0.8410.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.