Abstract
Multiaxial fatigue tests under non-proportional loading in which principal directions of stress and strain are changed in a cycle were carried out using a developed multiaxial fatigue testing machine which can load a push–pull and reversed torsion loading with cyclic inner and outer pressure. This paper presents the developed testing machine and experimental results under several multiaxial loading conditions including non-proportional loading. In strain control tests, the failure life is reduced in accordance with increasing inner pressure at each strain path. The failure life can be correlated by von Mises' equivalent stress amplitude relatively well independent of not only inner pressure but also loading path. In load control tests, the failure life is reduced largely by non-proportional loading but the influence of inner and outer pressure on the failure life is relative small.