Abstract

You have accessJournal of UrologyCME1 Apr 2023MP04-07 VOLATILOME ANALYSIS IN RENAL CANCER BY ELECTRONIC NOSE: A PILOT MONOCENTRIC STUDY Manuela Costantini, Alessio Filianoti, Alfredo Maria Bove, Umberto Anceschi, Aldo Brassetti, Mariaconsiglia Ferriero, Riccardo Mastroianni, Leonardo Misuraca, Gabriele Tuderti, Simone D'annunzio, Gennaro Ciliberto, and Giuseppe Simone Manuela CostantiniManuela Costantini More articles by this author , Alessio FilianotiAlessio Filianoti More articles by this author , Alfredo Maria BoveAlfredo Maria Bove More articles by this author , Umberto AnceschiUmberto Anceschi More articles by this author , Aldo BrassettiAldo Brassetti More articles by this author , Mariaconsiglia FerrieroMariaconsiglia Ferriero More articles by this author , Riccardo MastroianniRiccardo Mastroianni More articles by this author , Leonardo MisuracaLeonardo Misuraca More articles by this author , Gabriele TudertiGabriele Tuderti More articles by this author , Simone D'annunzioSimone D'annunzio More articles by this author , Gennaro CilibertoGennaro Ciliberto More articles by this author , and Giuseppe SimoneGiuseppe Simone More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003215.07AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Although challenging and highly expensive for health systems worldwide, no useful markers are available in clinical practice that aim to anticipate renal cancer diagnosis in the early stages in the context of wide population screening. Urine analysis by an electronic nose provides volatile organic compounds (VOCs) easily usable in the diagnosis of urological diseases. Some previous works suggested that dogs trained to smell urine could recognize lung, bladder, or breast cancer with various success rates, but no strong results have been reported in renal cancer (RCC) setting. In this study, we investigated the diagnostic potential of urinary VOCs profiling by enose in discriminating renal patients from healthy controls. METHODS: This prospective pilot study includes 252 individuals subdivided in two groups: 110 RCC patients, and 142 healthy controls. For each case, urine samples were collected, stabilized at 37°C, and twice analyzed using a commercially available electronic nose (Cyranose C320-32 sensors). Statistical analysis of the sensor responses was performed off-line using principal component (PCA) analyses and discriminant analysis (CDA). The best discriminating principal component groups were identified with univariable ANOVA analysis. We used the “leave-one-out method” to calculate the Cross Validated Accuracy (CVA), an estimate of accuracy of a predictive model in clinical practice. The discrimination accuracy of the built model was evaluated by ROC curves. RESULTS: Based on PCA analysis, 79/110 and 127/142 cases were correctly identified in RCC and healthy control cohorts, respectively (sensitivity 71.8%, specificity 89.4%; positive predictive value 84.4%, negative predictive value 80.3%). Results obtained with CDA demonstrated a correct classification in 81.7% of cases (p<0.001). At ROC analysis, the discrimination accuracy of the model area under the curve (AUC) was 0.85. Repeated analysis of a second measurement of urine samples provided comparable findings. CONCLUSIONS: This study provides a first evaluation of urinary volatilome in RCC. Urine VOCs profiling by e-nose seems a promising, non-invasive diagnostic tool with high accuracy in discriminating patients from controls. Ease of use, low costs and non-invasive nature makes this test a potential molecular biomarker in early RCC diagnostic settings. Source of Funding: Italian Ricerca Corrente 2022 © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e35 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Manuela Costantini More articles by this author Alessio Filianoti More articles by this author Alfredo Maria Bove More articles by this author Umberto Anceschi More articles by this author Aldo Brassetti More articles by this author Mariaconsiglia Ferriero More articles by this author Riccardo Mastroianni More articles by this author Leonardo Misuraca More articles by this author Gabriele Tuderti More articles by this author Simone D'annunzio More articles by this author Gennaro Ciliberto More articles by this author Giuseppe Simone More articles by this author Expand All Advertisement PDF downloadLoading ...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.