Abstract
BackgroundProsthesis factors account for a quarter of the dissatisfaction rates among post-total knee replacement (TKR) patients. In the Philippines, the available prostheses have pre-determined sizes and dimensions that are based on Caucasian morphometric data. This can pose a problem, since according to previous studies Asian knees have smaller dimensions compared to Caucasians. Since there is a paucity of research looking into the fitness of these prostheses to the Filipino knee, this study was pursued.MethodsThis study measured 675 knees of 675 adult Filipinos from January 2018 to December 2020. The morphometric measurements were performed on T1-weighted magnetic resonance images. The distal femoral morphometry included: the anteroposterior distance, lateral and medial anteroposterior distances, mediolateral distance, anterior and posterior mediolateral distances, and the femoral aspect ratio. The proximal tibial morphometry included: the anteroposterior distance, mediolateral distance, the medial and lateral anteroposterior distances, and the tibial aspect ratio. The patellar height, width, and thickness were also determined. Statistical analyses were done by using SPSS (version 26) and Microsoft Excel (version 2016).ResultsThe mean femoral medial and lateral anteroposterior distances were 57.6 mm and 57.1 mm, respectively. The femoral mediolateral distance was 69.3 mm, and the mean femoral aspect ratio was 1.21. The mean proximal tibial antero-posterior and mediolateral distances were 45.3 mm and 71.9 mm, respectively. The mean tibial aspect ratio was 1.66. Most TKR prostheses can be fitted to the Filipino knee but underhang on the mediolateral aspect is commonly observed in both the femoral and tibial components. The mean patellar height and width of Filipinos were 39.6 mm and 42.6 mm, respectively while the average thickness was 23.1 mm.ConclusionMost prostheses available in the Philippine and Asian markets can be fitted into Filipino knees albeit the underhang observed in the mediolateral aspects of both femoral and tibial components. Potential patellar complications are unlikely given the adequate thickness. To avoid the potential mismatch, the best approach is to design a prosthesis aptly suited for the Filipino knees.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.