Abstract

Abstract This paper addresses neutronics aspects of the design development of the Diagnostic Generic Equatorial Port Plug (EPP) in ITER. To secure the personnel access at the EPP back-end interspace, parametric neutronics analyses of the EPP radiation environment have been performed and practical shielding solutions have been found. Radiation transport was performed with the Monte Carlo MCNP5 code. Activation calculations were conducted with the FISPACT-2007 inventory code. The R2Smesh approach was applied to couple transport and activation calculations. Newly created EPP local MCNP5 model was devised by extracting the EPP and adjacent blanket modules from the ITER Alite-4.1 model with proper modification of the EPP geometry in accordance with recent 3D CAD CATIA model. The EPP local model reproduces the EPP neutronically important features and allows investigation of the EPP neutronics effects in isolation from all other ITER components. Thorough EPP parametric analyses revealed dominant effect of gaps around EPP and several EPP design improvements were implemented as the outcomes of the analyses. Gap labyrinths and streaming stoppers inserted into the gaps were shown are capable to reduce the shutdown dose rate which is below the 100 μSv/h limit of personnel access and by 2 orders of magnitude less than the value in the model with straight gaps.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call