Abstract

Measured and calculated neutron and gamma-ray energy spectra from approx. 14 MeV neutrons streaming through a stainless-steel duct having a length-to-diameter ratio of 4.6 are compared. The 1.45-m-long duct is imbedded in a concrete block. The spectra were measured with an NE-213 liquid scintillator as a function of detector location relative to the mouth of the duct. The calculated data were obtained using the Monte Carlo code MCNP and the discrete ordinates code DOT 4.3. The calculations were performed using a two-dimensional cylindrical model of the experiment with symmetry about the duct axis. The measured and calculated neutron and gamma-ray spectra are compared at two distances from the mouth of the duct and at detector locations on and off the duct axis. The neutron spectra calculated with MCNP agree with the measured data within approx. 5 to 50% at all detector locations. The data calculated using the discrete ordinates method are in good agreement with the experiment for the cases where the detector is on axis but are in poor agreement at the off axis detector locations. The gamma-ray spectra calculated with both radiation transport methods are in good agreement (approx. 5 to 25% depending on photon energy) with themore » measured spectra.« less

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.