Electro Mechanical Reshaping (EMR) with platinum needle electrodes has been recently developed to shape cartilage without conventional cut and suture surgery. This study investigates the relationship between the voltage applied, the electrical current measured during EMR, and the resulting shape. Monitoring the electrical current provides information to model the electro-chemistry, which will aid in determining the onset of shape stabilization. Porcine costal grafts, rabbit auricular, and porcine auricular tissue were bent into a 90° angle using a moulage. Platinum needle electrodes were then placed in contact with the cartilage and a constant voltage was applied for a set time. The electrical current was measured during the process and total charge transferred was calculated. The cartilage specimen was then removed from the jig and photographed after one minute in order to determine the resulting bend angle. Results show that a higher current in tissue is produced with increasing applied voltage. Each current trace is unique and is dependent on tissue thickness and inter-electrode distances. Understanding the electrical current process ultimately leads to optimizing EMR and feedback control. Voltage, for example, could be varied in real-time during EMR to produce a constant chemical reaction rate and potentially reduce total tissue dehydration in contact with electrodes. In conclusion, electric current traces provide information about chemical kinetics during EMR that depend on exposure settings, and monitoring these traces is an important step in optimizing the reshaping process.

Highlights

  • Electro Mechanical Reshaping (EMR) with platinum needle electrodes has been recently developed to shape cartilage without conventional cut and suture surgery

  • This study investigates the relationship between the voltage applied, the electrical current measured during EMR with platinum needles, and the resulting shape

  • Monitoring the electrical current provides information to model the electro-chemistry, which will aid in determining the onset of shape stabilization

Read more

Summary

Introduction

Electro Mechanical Reshaping (EMR) with platinum needle electrodes has been recently developed to shape cartilage without conventional cut and suture surgery. Monitoring of electrical current in rabbit and porcine cartilage tissue during electromechanical reshaping Cyrus Manuel*, Allen Foulad, Dimitry Protsenko, Brian Wong From 2nd Scientific Meeting of the Head and Neck Optical Diagnostics Society San Francisco, CA, USA.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.