Abstract

Wavelength modulation-direct absorption spectroscopy (WM-DAS) has the advantages of both direct absorption spectroscopy (DAS) measurable absorptivity function and wavelength modulation spectrum (WMS) with high signal-to-noise ratio (SNR). In this paper, the WM-DAS spectrum is used to measure the absorptivity of 4300.7 cm<sup>–1</sup> line of CO molecule and the detection limit is as low as 4 × 10<sup>–7</sup> (200 s) at 0.5 m optical path, room temperature and low pressure. Then, through combining the WM-DAS spectrum with a 120 m long optical path Herriott cell, at room temperature and atmospheric pressure, the standard deviation of the fitting residual error of the absorptivity function is reduced down to ~5.1 × 10<sup>–5</sup> (1 s). Finally, different concentrations of CO are continuously monitored by long-path WM-DAS measurement system, and compared with the results obtained from the cavity ring-down spectroscopy (CRDS). The experimental results show that the measurement results from the long-path WM-DAS and CRDS method are the same. The detection limit of CO concentration in long-path WM-DAS system is as low as 0.9 ppb (200 s), and the WM-DAS system is simple and the measurement speed is much faster than CRDS. At the same time, the long-path WM-DAS system is used to continuously monitor the atmospheric trace CO concentration and trend for one month, and the measured results are highly consistent with those from the China Environmental Monitoring Station.

Highlights

  • 图 5 (a) Wavelength modulation-direct absorption spectroscopy (WM-direct absorption spectroscopy (DAS)) 测量的 CO(4300.7 cm–1) 吸收系数函数, 采集 103 周期, 总用时 1 s; (b) cavity ring-down spectroscopy (CRDS) 测量的 CO(6383.09 cm–1、 线强度约为 4300.7 cm–1 的 0.77 %) 吸收系数函数, 平均 103 次, 总用时 4 h Fig. 5. (a) CO (4300.7 cm–1) absorption coefficient function measured by WM-DAS, 103 cycles of collection, and the total time is ~1 second; (b) absorption coefficient function of CO (6383.09 cm–1, the line strength is about 0.77% of 4300.7 cm–1) measured by CRDS, with an average of 103 times, with a total time of 4 hours

  • 为了分析长光程 Wavelength modulation-direct absorption spectroscopy (WM-DAS) 和 cavity ring-down spectroscopy (CRDS) 的检测 限, 实验中将 Herriott 池和衰荡腔通过管线串联, 确保两者的温度、压力和组分浓度完全一致

Read more

Summary

Introduction

波长调制-直接吸收方法在线监测大气中CH4和CO2浓度 Monitoring of ambient methane and carbon dioxide concentrations based on wavelength modulation-direct absorption spectroscopy 物理学报. 基于傅里叶变换的波长扫描腔衰荡光谱 Wavelength-scanned cavity ring down spectroscopy based on Fourier transform 物理学报. 基于光强与吸收率非线性同步拟合的吸收光谱测量方法 Laser intensity and absorbance measurements by tunable diode laser absorption spectroscopy based on non-line fitting algorithm 物理学报.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call