Abstract

Based on the principle of heat transfer, a monitoring software package about identifying erosion profile of submerged arc furnace with “freeze” lining is developed by VC++. Reliability of traditional lining without monitoring system and “freeze” lining with monitoring software are evaluated by Fuzzy FMECA Method. There is a conclusion can be draw that the hazard rating of submerged arc furnace with traditional lining is 2.9094.This value of “freeze” lining is 2.1087.The result indicates that adopting the “freeze” lining with monitoring software can drop the potential safety hazard effectively and reduce casualties.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.