Abstract

ABSTRACT Electrical resistance (ER) probes are a technique used to monitor the corrosion rate (CR) of metals in a wide range of applications and industries. However, limited data comparing CR measured with ER-probes, weight loss and electrochemical methods is available. The aim of this work is to provide data regarding the reliability of CR measurements with ER-probes by comparison with LPR, EIS and weight loss measurements and to provide suggestions for designing ER-probes depending on the expected corrosion mechanism and CR. To evaluate the ER-probes reliability in CR measurements, both uniform and localised corrosion in four different environments were studied. CRs obtained with ER-probes showed good agreement with weight loss and electrochemical measurements. Numerical models were used to optimise ER-probe geometry regarding the expected corrosion type and CR, and to study the effect of Joule heating. Design charts were proposed to support ER-probes design concerning the expected CR in certain applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.