Abstract
Beam-column joint is the gap in the modern ductile design of building. Especially under the earthquake loading this is more susceptible to damage. Due to brittle nature of failure this type of failure cannot be afford. Since 1970’s this areas is under the light of research, but with the paper of Park and Paul, It got momentum. But still due to versatile nature of the joints core behaviour, the problem is still persisting. Though many international codes recommend the moment capacity ratio at beam column joint to be more than one, There are discrepancies among the major international codes with regard to MCR. Indian standard codes for design of RC framed buildings are silent on this aspect. Draft 13920 (2014) code suggests a value of MCR similar to other international codes without proper theoretical basis. Hence a rational study is required on the values of MCR. A computationally attractive procedure for calculating flexural capacity of column developed for determining MCR at a beam-column joint. To reach at an appropriate and acceptable MCR for capacity design of RC framed building reliability based approach is done. This research deals with the fragility and reliability analysis of five, seven and ten storey RC frames designed using various values of MCR ranging from 1.0 to 3.2. The RC frames are designed as per IS 1893 (2002) for all seismic zones. Hazard curves required of various seismic location in India (like zone II, III, IV and V) has been selected from National Disaster Management Authority, Government of India. Seismic risk assessment of all the designed buildings is conducted and based on the achieved Reliability Index and the Target Reliability Index minimum value of Moment Capacity Ratio (MCR) is suggested.
Highlights
Jain et al, (2006) proposed that, when a reinforced concrete moment resisting frame is subjected to seismic loads, at beam-column joint, summation of moment of resistances of columns should be greater than or equal to 1.1 times summation of moment of resistance of beams framing into it as in equation (2)
Fragility curves for 5-storey 3-bay framed building is developed as per methods discussed above for different Moment Capacity Ratio (MCR) values for the two damage states Gr3 and Gr4
Performance of 10-Storey 3-Bay Building Frames 3) The 10-storey building shows ductility increases up to MCR 1.47 and it decreases for MCR 1.7
Summary
Ground motions occur both horizontally and vertically in random fashions which cause structures to vibrate and induce inertia forces during Turkey earthquake
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.